Compressor runs, but evaporator does not

1. Faulty blower
motor or broken wire
connection

Evaporator coil probably frozen

•

Shut off power to condensing unit

•

Call a CERTIFIED HVAC service technician for repair

•

2. Defective low
pressure switch not
shutting compressor off
when pressure drops

Compressor would continue to run when thermostat

•

is satisfied and shuts blower and solenoid off. When
space warms up to set point, blower starts and the
system runs normally.
Prolonged running without refrigerant flow will

•

damage or destroy compressor. If this condition
exists, call a CERTIFIED HVAC service technician.

Compressor short cycles, which is different from running intermittently

1. System pressure
controls defective.

Call a CERTIFIED HVAC service technician to verify and
repair.

2. System low on
refrigerant.

Observe for flashing in refrigerant sight glass located
in 1/4” copper tube at condensing unit. If flashing with
bubbles, call a CERTIFIED HVAC service technician for
leak location, repair, and adding refrigerant.

3. Condenser fan motor
defective

Fan does not run with compressor.

•

¼” copper tube at sight glass – very hot, compressor

•

very hot, runs short time, shuts off.
Shut power off to condensing unit

•

Call a CERTIFIED HVAC service technician for repair.

•

4. Compressor starting
components defective.

Compressor very hot and hums when trying to start.

•

Shut power off to condensing unit.

•

Call a CERTIFIED HVAC service technician.

•

Evaporator coil freezes

1. Air filter, if
equipped, dirty

Clean or replace filter

2. Evaporator coil and/
or blower dirty

Clean coil and blower

3. Thermostat set point
too low.

Set point should not be lower than 50°. If so, increase to
above 50°

4. System low on
refrigerant

Check refrigerant “sight glass” in 1/4” tubing. Check
for bubbles after system has run for several minutes. If
bubbles present, call a CERTIFIED HVAC service technican.
If sight is clear of bubbles, refrigerant level is OK.