TROUBLESHOOTING

Fault Cause

Solution

Water leaking from unit

1. Condensate drain
clogged

Clear out drain

2. Evaporator coil
frozen

Clean the coil and / or fan wheel

3. Drain line improperly
installed

Call a CERTIFIED HVAC service technician.

Wine cellar temperature above thermostat set point

1. Large quantity of
warm wine placed in
cellar

Allow time for wine to cool

2. Wine Cellar Door left
open for long period.

Close Door. Allow time for wine to cool.

3. No power to
either fan coil unit or
condensing unit

Fan Coil
Is the thermostat display illuminated?
If not, check power supply switch, if equipped. Ensure it
is in the ON position.

If on, check to see in the breaker is tripped.
If tripped, reset and check display.
If display “Wine” bar is illuminated, wait for time delay to
expire. Wine light blinks during time delay countdown.

Check to see if “On” bar indicator illumination appears
at which time the blower and cooling should start
If blower starts and no cooling follows, check power
supply to condensing unit.

Check breaker to condensing unit. If tripped, check to
see if compressor is hot – too hot to touch. If so, allow
to cool for one (1) hour before resetting breaker.

After cooling, reset breaker and note whether it remains
set or trips off. If it trips, call a CERTIFIED HVAC service
technician for repair.