2.3.10

LNB DC Power

The unit may feed DC power to an external antenna-mounted LNB using either the RF-In
connector’s center-pin or a terminal on the rear-panel terminal strip (with an external DC power
inserter). The nominal voltage supplied is +17 to +24 VDC, while the maximum load current is
250 mA. The output is short-circuit protected by a thermal fuse. An internal jumper (J27) is
used to enable/disable DC power on the RF-In center-pin. Once that jumper has been set, the
LNB power can be turned on via the front panel menu.
LNB DC Power is available in all audio and video modes.

2.4

LOCAL CONTROLS AND INDICATORS

2.4.1 Front

Panel

See

Figure 3

(Page 26) for a view of the front panel.

2.4.1.1

Front Panel Display

The front-panel includes a 2-line by 20-character display to support the monitor/control
interface. See

Table 20

(Page 39), and

APPENDIX B

for details on the messages displayed

there, as well as the menus supporting the keypad interface described in Section

2.4.1.2

(Page

20).

2.4.1.2

Front Panel Keypad

The front-panel includes a keypad for user input. The keys are right, left, up, down arrows and
SELECT, and ENTER. See Section

3.8.4

(Page 38), and

APPENDIX B

(Page 47) for details on

their use.