Wegener Communications 4422 User Manual

Page 69

Advertising
background image

Page 69

Page 69 of 72

UTY4422-002

7.3 Modem baud/Password B=( 9600 , 19.2k ), P-word = ___ ___ ___ ___ ___ ___ ( PASSWD )
7.4 Local Terminal/front-panel Control: ( Enabled / Disabled )
7.5 Printer baud/parity: Baud =( 9600 , 19.2 k ) ; Parity =( odd , even , none )
7.6 Aux. Data PID [hex]: ( _________________, 1ffe )
7.7 Aux. Data Baud/Parity: B=( 1200, 2400, 4800, 9600, 19.2k, 38.4k ); P=( odd , even , none )

8.0 Misc. Audio/Video Setup Parameters
8.1 PCR mode ( auto-adjust to data-rate , static ! ) -- “Auto-adjust” required with DVT2000
8.2 PCR offset [hex]: ( _____________ , -3000 ! ) -- Applicable if “static” above is selected
8.3 Video Pedestal Setup: ( Disabled, Enabled ! ) -- “Enabled” matches DVT2000
8.4 Video Aspect Ratio: ( Auto Detect ! , 16:9, 4:3 )
8.5 Audio delay [hex]: ( _____________ , 0 ! ) – Sets A/V sync, default value is hex for ‘0’ decimal
8.6 Horiz Delay: NTSC ( __________ , 34 ! ) ; PAL ( ____________ , 3e ! )
8.7 Optional outputs home-screen alarm/warning bitmask on failure:
Sync Data: ( None , Warning , Alarm ); ASI Transport: ( None , Warning , Alarm )
Serial Digital Video [D1]: ( None , Warning , Alarm )

9.0 Network Settings
9.1 COMPEL PID [hex]: ( _________ , 1026 ! ) -- Next alternate is usually 1030
9.2 Wegener C/A PID [hex, if applicable]: ( _________ , 1028 ! ) -- Next alternate is usually 1032
9.3 Netcon Lock: ( Locked , Unlocked )
9.4 Shared Mode ( Shared , Protected )
9.5 COMPEL Required ( Required , Not required )
9.6 Tag Bypass: ( No ! , Yes ) -- “Yes” is also known as “ISOG-enabled”
9.7 Timeouts:

#

Description

Allowed Range

Default

Change from Default

1

Fade

0 - 30 seconds

15 seconds !

2

Install

0 - 4660 hours

4660 hours !

3

Carrier Search

0 - 4660 hours

48 hours !

4

No COMPEL

0 - 4660 hours

2 hours !

5

COMPEL Seek

0 – 4660 hours

5 minutes !

6

Header Search

0 – 4660 hours

48 hours !

10.0 Information on Option Module Location:
The following are the optional Modules cards that can be added to the UTY4422 unit.

Maximum Qty. Preferred Module Location inside unit
each per unit (* For signal option card)
(** Only location available)

A. Balanced Audio Card 2 Module #1 * See configuration below

B. 14 Function Relay Card 1 Module #1 * See configuration below

C. 2 Port ASI Input Card 1 Module #1 ** See configuration below

D. ASI Output Card 1 Module #1 * See configuration below

E. Sync Data Output Card 2 Module #1 * See configuration below

F. 4 Port RF Input Switch Card 1 Module #2 ** Not configurable