background image

Dimensions in
parentheses are in
millimeters unless
otherwise specified.

14

I N S T A L L A T I O N O P T I O N S

The Wolf E Series double oven may be
installed in combination with a Wolf warming
drawer. Refer to the warming drawers
section for specifications.

IMPORTANT NOTE: Unless you are using
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset instal-
lation, it is recommended that the electrical
supply be placed in an adjacent cabinet within
reach of the conduit. Choose the location
shown in the illustration that best suits your
installation.

E S E R I E S B U I L T - I N O V E N S

49

5

/

8

"

(1260)

OPENING

HEIGHT

50

15

/

16

"

min (1294)

FLUSH

INSET

HEIGHT

30

3

/

8

"

min (772)

FLUSH INSET WIDTH

28

1

/

2

"

(724)

OPENING WIDTH

5"

(127)

4"

(102)

E

E

E

E

36"

(914)

RECOMMENDED CABINET WIDTH

33"

min (838)

24"

min

(610)

OPENING

DEPTH

1"

(25)

25"

min

(635)

FLUSH

INSET

DEPTH

7

/

16

"

(11)

7

/

8

"

(22)

ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)

67"

typical

(1702)

SIDE VIEW

TOP VIEW

I N S T A L L A T I O N S P E C I F I C A T I O N S

E Series Built-In Double Oven

Flush Inset Installation

Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.

For flush inset installations, cabinet materials

must be able to withstand temperatures up

to 195˚F (90˚C) to avoid damage from high

temperatures during self-clean.