Wolf Appliance Company SO30F/S User Manual

Page 46

Advertising
background image

W O L F E L E C T R I C C O O K T O P S

46

2"*

min (51)

CUT-OUT TO

COMBUSTIBLE

MATERIALS

(BOTH SIDES)

18"

(457)

36"

(914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

30"

(762)

COUNTERTOP TO

COMBUSTIBLE

MATERIALS

ABOVE COOKTOP

30-INCH OVEN OPENING

33"

(838) RECOMMENDED

CABINET WIDTH

30"

min (762)

13"

max

(330)

24"

min

(610)

4"

min (102)

SEE COUNTERTOP

CUT-OUT BELOW

SEE COUNTERTOP

CUT-OUT BELOW

*Minimum clearance from both side edges and back edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.

E

10"

(254)

4"

min (102)

TO OVEN

OPENING

3

1

/

2

"

(89)

4

1

/

2

"

(114)

21"

(533)

OVERALL

DEPTH

30"

(762)

OVERALL WIDTH

5

1

/

2

"

(140)

4

1

/

4

"

(108)

CONDUIT

Countertop Cut-Out Dimensions

O V E R A L L D I M E N S I O N S

New Model CT30EU

I N S T A L L A T I O N S P E C I F I C A T I O N S

New Model CT30EU

S P E C I F I C A T I O N S

New Model CT30EU

Overall Width

30" (762)

Overall Height

4

1

/

4

" (108)

Overall Depth

21" (533)

Heating Elements

Three

Temperature Zones

Four

Max Element Power
Triple

900 / 1800 / 2500 W

Singles

1200 W and (2) 1800 W

Singles with Bridge

4400 W

Cabinet Width

33" (838) rec
30" (762) min

Cabinet Depth

22

3

/

4

" (578) min

Height Clearance

4

1

/

2

" (114) min

Cut-Out Width

28

3

/

8

" (721)

Cut-Out Depth

19

3

/

8

" (492)

Electrical Supply

240 V AC / 60 Hz / 40 amp
208 V AC / 60 Hz / 30 amp

Conduit

4' (1.2 m) flexible 3-wire

Electrical Rating

8.1 kW at 240 V
6.1 kW at 208 V

Shipping Weight

45 lbs (20 kg)

The outer diameter of the heating elements are
10" (254), two 8" (203) and 6

1

/

2

" (165). The

bridge with elements is 8" (203) x 17" (432).

IMPORTANT NOTE: A minimum height clearance
of 6

1

/

4

" (159) is required between countertop and

any combustible surface directly below cooktop.

I N S T A L L A T I O N O P T I O N S

The Model CT30EU unframed electric cooktop
can be mounted flush with the top of the
countertop or as a frameless installation
sitting on top of the countertop surface. In
either installation the cooktop cut-out dimen-
sions are the same. If mounted flush with the
countertop, a recessed area surrounding the
cooktop cut-out is required.

IMPORTANT NOTE: Flush mount installations
are intended for granite, solid surface or stone
countertop surfaces only. If the cooktop is to
be mounted flush with the countertop, fabrica-
tion of the recessed area must take place
before the countertop installation. A template
of the countertop cut-out will be provided with
the cooktop for fabrication purposes.

A Wolf 30" (762) L Series or E Series single
oven may be installed below the Model
CT30EU. For this installation, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply be
placed in the base cabinet to the right of the
oven. Refer to the built-in ovens section for
additional specifications.

28

3

/

8

"

(721) COOKTOP

CUT-OUT WIDTH

1

5

/

16

"

(33)

RADIUS

2

7

/

16

"

(62)

19

3

/

8

"

(492)

COOKTOP

CUT-OUT DEPTH

7

/

16

"

(11) RADIUS

30

1

/

8

"**

(765)

RECESSED AREA FOR

FLUSH MOUNT INSTALLATION ONLY

FRONT OF COUNTERTOP

1

9

/

16

"

(40)

21

1

/

8

"**

(537)

RECESSED AREA

FOR FLUSH MOUNT

INSTALLATION ONLY

**Minimum dimension, but may be exceeded by up to

1

/

8

" (3).

RECESSED AREA FOR

FLUSH MOUNT INSTALLATION ONLY

5

/

16

"

(8)

7

/

8

"

(22) max

COUNTERTOP

PROFILE

2"*

(51)

Unit dimensions may vary to ±

1

/

8

" (3).

IMPORTANT NOTE: For flush mount applications,
it is recommended that you measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.

Available November 2007

NEW

Advertising