B L O W E R C O N S I D E R A T I O N S

Wolf cooktop wall and island hoods are shipped

without the blower assembly. Internal, in-line

and remote blower assemblies are available. For

wall hoods, the remote blower can be mounted

on the roof or an exterior wall. For island hoods,

the remote blower will be mounted on the roof.

The blower will vary in size and is dictated by

the cooking surface, the volume of air that needs

to be moved and the length of the duct run. A

straight, short duct run with a limited number of

elbows and transitions will allow the ventilation

hood to perform most efficiently.

A remote mounted blower will minimize the

amount of blower noise, but will not eliminate

the noise completely. All remote blowers will

require a transition to a 10" (254) duct.

IMPORTANT NOTE: Install these ventilation

hoods only with a Wolf blower.

WALL CAP

OR REMOTE BLOWER

COOKTOP

WALL HOOD

DUCTWORK INSTALLATION

THROUGH ROOF

DUCTWORK INSTALLATION

THROUGH WALL

8" (203) ROUND

VERTICAL DISCHARGE

8" (203) ROUND DUCT

CHIMNEY FLUE EXTENSION

TELESCOPIC CHIMNEY FLUE

8" (203) ROUND ELBOW

8" (203) ROUND DUCT

6

7

/

8

"

(175) OR

9

1

/

4

"

(235)

21"

(535)

24"

TO

30"

(610 – 762)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

ROOF CAP OR REMOTE BLOWER –

TRANSITION FROM 8" (203) TO 10" (254) DUCT

REQUIRED FOR REMOTE BLOWER

8" (203) ROUND DUCT

8" (203) ROUND ELBOW

CHIMNEY FLUE EXTENSION

TELESCOPIC CHIMNEY FLUE

8" (203) ROUND DUCT

24"

TO

30"

(610 – 762)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

COOKTOP

ISLAND HOOD

DUCTWORK INSTALLATION

THROUGH ROOF

DUCTWORK

INSTALLATION

THROUGH

EAVE –

INTERNAL

OR IN-LINE

BLOWER ONLY

8" (203) ROUND

ELBOW

EAVE VENT

9

1

/

4

"

(235)

27"

(686)

8" (203) ROUND

VERTICAL

DISCHARGE

ROOF CAP OR REMOTE BLOWER –

TRANSITION FROM 8" (203) TO 10" (254) DUCT

REQUIRED FOR REMOTE BLOWER

D U C T I N G C O N S I D E R A T I O N S

IMPORTANT NOTE: All Wolf cooktop hoods

must be vented to the outside. Use only metal

ductwork.

Wolf cooktop wall and island hoods have an 8"

(203) round vertical discharge. Ducting can run

through the roof, external wall or eave. Ducting

through an eave requires an internal blower.

Refer to the illustrations below.

Wolf cooktop wall and island hoods will operate

most efficiently when ductwork does not exceed

50' (15 m) in length.

Local building codes may require the use of

make-up air. Consult your local HVAC profes-

sional for specific requirements in your area.

Refer to the cooktop ventilation recommenda-

tions on pages 115–116.