O V E R A L L D I M E N S I O N S

Downdraft Systems

Models DD30I / DD30R

2

3

/

8

"

(60)

30"

(762)

9

1

/

16

"

(230)

26

1

/

4

"

(667)

1

1

/

2

"

(38)

DEPTH OF

DOWNDRAFT CHIMNEY

Models DD36I / DD36R

36"

(914)

32

1

/

4

"

(819)

2

3

/

8

"

(60)

9

1

/

16

"

(230)

1

1

/

2

"

(38)

DEPTH OF

DOWNDRAFT CHIMNEY

Specifications on the following pages provide

overall dimensions, blower and ducting consider-

ations, and installation specifics for downdraft

ventilation systems. Also refer to the cooktop

ventilation recommendations on pages 115–116.

If a Model DD30 is installed in combination with

two integrated modules, an integrated module

support for downdraft ventilation is required.

Contact your Wolf dealer for information on

accessory components.

P L A N N I N G I N F O R M A T I O N

Wolf downdraft ventilation systems are available

in 30" (762), 36" (914) and 45" (1143) widths.

The downdraft should be at least as wide as the

cooking surface.

Downdraft Model DD30 will fit most 30" (762)

wide cabinets, Model DD36 will fit most

36" (914) wide cabinets and Model DD45 will fit

most 45

1

/

2

" (1156) wide cabinets. It is recom-

mended that oversized cabinets be used for

easier installation. Cabinet backs may need to be

removed.

IMPORTANT NOTE: To install a downdraft

system and a Wolf cooktop, you must allow for

a minimum 25

1

/

8

" (638) flat counter space from

front to back. A countertop with a raised lip

and/or backsplash may not allow enough space

for proper installation. 2

3

/

8

" (60) of flat counter-

top is required behind the cooktop and 1

3

/

4

" (44)

is necessary between the back edge of the

cooktop and inside of cabinet back.

IMPORTANT NOTE: This appliance must be

used with a Wolf-approved control module and

top cover.

The remote-mounted control module is available

as a sales accessory for Models DD30 and DD36

and is included with Model DD45. Installation of

the control module must be within 10' (3 m) of

the downdraft assembly and a minimum of 4"

(102) from the outer edge of cooktop element or

burner. You will be required to drill three holes

and connect the downdraft to the control

module with the provided wire.

45

1

/

2

"

(1156)

41

1

/

4

"

(1048)

2

3

/

8

"

(60)

9

1

/

16

"

(230)

1

1

/

2

"

(38)

DEPTH OF

DOWNDRAFT CHIMNEY

Models DD45I / DD45R

Dimensions in
parentheses are in
millimeters unless
otherwise specified.