Control panel operation – WhisperKool 081310 User Manual

Page 15

Advertising
background image

Page 13

CONTROL PANEL OPERATION

Button

Normal Functions

ON/OFF

• The ON/OFF button allows the customer the convenience of turning the refrigeration system

ON or OFF, from the control panel. This feature does not disconnect power from the unit, and

the condenser fan will continue to run in the OFF position. In order for the power to be shut

off from the unit, the power cord must be unplugged from the wall receptacle.

• Press the ON/OFF button once for button application.

Up and

Down

Arrows

• Use these buttons to scroll up or down the CPSM menu.

• Displays the Highest and Lowest temperature sensed by the Bottle Probe. This feature allows

the customer instant access to the recorded data applicable to the Bottle Probe Tempera-

tures, it can be easily reset to reflect current temperatures.

1. Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Temperature (Hi/

Lo) sensed by the Bottle Probe, will be displayed.

2. To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed on the

Digital Display, continue to hold the “Set” button until “rst” appears on the digital display and

then blinks. This will erase the past recorded “Temperature Data History” and start recording,

from the current time and temperature, forward. Temperatures displayed would reflect Bottle

Probe Temperatures from that point in time, and beyond.

3. The Hi/Lo feature should be reset at initial “Start-Up” and after the Cellar or Cabinet has ob-

tained normal operating temperatures, which is generally 55°F.

Cellar

PreChill

(CPC)

The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC logo will be

displayed on the digital display. The CPC feature can be terminated by pressing the Up button

for 3-5 seconds, or the feature will self terminate after 6 hrs.

1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm Product.

The feature will shift the Set Point down to a lower setting of 52°F, for the next 6 hours. After the

6 hour time period, the Set Point will automatically return to the original Set Point.

2. The CPC feature can be conveniently adjusted to the customer’s specific needs, by accessing

the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode Instruc-

tions.

Note: This feature is not available on the Remote Key Pad application.

Evaporator Fan

Cellar “Pre-Chill” Button

3-5

Set Button

View Set Point

1

Change Set Point

3-5

SET + Down = CPSM

3-5

Reset Hi & Lo Button

3-5

ALARM

Pre-Chill Display

Control “ON/OFF” Button

Turns the Cooling Unit
“ON/OFF”

1

Defrost

Compressor

Energy Reduction

Hi Bottle Temp History & Scroll
Button

1

Low Bottle Temp History & Scroll

Button

1

Energy Reduction
Button

1

Condenser Fan

Note: The 1 or the 3-5 stands for the amount of time (in seconds) that the button must be held.

Advertising