Split system installation – WhisperKool 081310 User Manual

Page 8

Advertising
background image

Page 6

GSM-01 081310

General Installation Guidelines and Instructions

WhisperKOOL requires that a certified HVAC technician install and charge all split systems. Please take a

moment to review state and city building codes to ensure the safe and proper installation of the system.

Electrical Needs

WhisperKOOL split systems requires a dedicated 110-volt 20-amp circuit. The system draws a large amount

of amps at initial start up. By designating a dedicated circuit breaker, you will guarantee that the system has

enough power to run effectively. Contact an electrician for assistance with the installation of this dedicated

electrical circuit:

1. Match the electrical outlet to the plug provided on the WhisperKOOL unit.

2. Provide a dedicated circuit and wiring for the unit.

3. Provide a weatherproof plug for units mounted outside.

WE RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER (GFI) WITH THIS PRODUCT.

In case the system should lose power, press the reset button and attempt to turn the unit back on. Check

the home/main circuit breaker. If the unit does not respond properly, refer to the Troubleshooting section
on

page 17.

Condensing Unit Preparation

Note: The condensing unit is shipped with a protective foam pad/ block to prevent damaging tubing

against the condenser coil fins. Please ensure that this pad is removed prior to operation.

SPLIT SYSTEM INSTALLATION

*A Low Ambient Control is used on most models,

a Fan Cycling Switch is used otherwise.