Compressor runs, but evaporator does not

1. Faulty blower

motor or broken wire

connection

• Evaporator coil probably frozen
• Shut off power to condensing unit
• Call a CERTIFIED HVAC service technician for repair

2. Defective low

pressure switch not

shutting compressor off

when pressure drops

• Compressor would continue to run when thermostat is

satisfied and shuts blower and solenoid off. When space

warms up to set point, blower starts and the system

runs normally.

• Prolonged running without refrigerant flow will

damage or destroy compressor. If this condition exists,

call a CERTIFIED HVAC service technician.

Compressor short cycles, which is different from running intermittently

1. System pressure

controls defective.

Call a CERTIFIED HVAC service technician to verify and

repair.

2. System low on

refrigerant.

Observe for flashing in refrigerant sight glass located in 1/4”

copper tube at condensing unit. If flashing with bubbles,

call a CERTIFIED HVAC service technician for leak location,

repair, and adding refrigerant.

3. Condenser fan motor

defective

• Fan does not run with compressor.
• ¼” Copper tube at sight glass – very hot, compressor

very hot, runs short time, shuts off.

• Shut power off to condensing unit
• Call a CERTIFIED HVAC service technician for repair.

4. Compressor starting

components defective.

• Compressor very hot and hums when trying to start.

• Shut power off to condensing unit.

• Call a CERTIFIED HVAC service technician.

Evaporator coil freezes

1. Air filter, if equipped,

dirty

Clean or replace filter

2. Evaporator coil and/

or blower dirty

Clean coil and blower

3. Thermostat set point

too low.

Set point should not be lower than 50°. If so, increase to

above 50°

4. System low on

refrigerant

Check refrigerant “sight glass” in 1/4” tubing. Check for bubbles

after system has run for several minutes. If bubbles present,

call a CERTIFIED HVAC service technican. If sight is clear of

bubbles, refrigerant level is OK.