Adjusting the energy smart, Module/operational modes, Operating mode descriptions – Whirlpool Energy Smart 188414 User Manual

Page 11: Water temperature adjustment, F/°c

Advertising
background image

11

Operating Mode Descriptions

The operating modes can be changed by touching

the desired mode icon on the Energy Smart

®

Module

(See Figure 10). NOTE: All buttons on the Energy

Smart

®

Module are touch sensitive and require only a

light touch to actuate.

Adjusting the Energy Smart

®

Module/Operational Modes

Water Temperature Adjustment

IMPORTANT: Before attempting to adjust the thermostat, read the “Water Temperature Regulation” section on page 10.

If the instructions are not clear, contact a qualifi ed person.

The water temperature can be adjusted from 80° F to 150° F. Use the Up and Down Buttons to set the

desired temperature.

ENERGY SMART

®

- This mode is

used to save energy by monitoring

usage and adjusting the set point

to match the water draw usage pat-

tern (Temperature set point can be

changed).

STANDARD - Pressing this button

will allow the temperature set point

to be set directly.

VACATION MODE - The control-

ler adjusts the water temperature

to approximately 60

0

F. This mode

is recommended when the water

heater is not in use for a long period

of time. This mode minimizes en-

ergy consumption and prevents the

water heater from freezing during

cold weather.

GRID ENABLED - Pressing this

button will enable or disable a re-

quest for grid control (see page 13).

CONTROL PANEL LOCK - Holding

this button for more than 3 seconds

switches the lock mode on or off.

When the User Module is locked, a

symbol and “Lock” text will be visible

on the display.

0

F/

0

C - This button switches the

display to show the set temperature

in Fahrenheit or Celsius.

Fault condition will display an “E”

followed by two digit fault code with

Alert Icon fl ashing. (see diagnostic

code chart page 17).

Element Functioning Icon - indicates

power is on at either upper or lower

element circuits and both are work-

ing properly.

°F/°C

°F/°C

F

GRID

ENABLED

VACATION

STANDARD

ENERGY

SMART

Control Panel
Lock Icon

Operational
Mode Buttons

Element
Functioning
Icon

Water
Temperature
Set Point

Temperature
Down (Decrease)
Button

Temperature
Up (Increase)
Button

LCD Display Panel
Lock Button

Fahrenheit/
Celsius Temper-
ature Display
Button

Energy Smart®

Module (ESM)

Electronic
Thermostat
(ET)

NOTE: The Electronic Thermostat (ET) is designed so that it
may control the water heater without the Energy Smart

®

Module

(ESM) being operated, see page 12.

Figure 10: Energy Smart

®