Wiring is enclosed in approved conduit (if required

by local codes).

The water heater and electrical supply are properly

grounded.

Always reference the wiring diagram for the correct electri-

cal connection. The complete wiring diagram can also be

found on the top of the water heater near the junction box

cover.
When installing the electrical wiring to the water heater

Although this water heater is equipped with “Dry-fi re”

protection, be sure the tank is completely fi lled with

water, and all air is purged from the tank before

making any electrical connections (See Figure 7).

NOTE: Applying electrical power to elements that are not submerged
in water will destroy them. The manufacturer will not warranty any
elements damaged in this manner.

Figure 7
Heating Element

Bang

Energy Smart®
Module (ESM)

Figure 8B
Electronic Thermostat (ET)

Electronic
Thermostat (ET)

Wiring Harness
( Junction Box )

Wiring Harness

( ET to ESM )

Ground Wire

( Attached To T-Stat Bracket Screw )

Figure 8A
Junction Box

Junction Box Cover

Red Wires
(3)

Black Wires
(3)

Ground Wires

Smart Grid
Cover

1/2” Conduit
Connection

From Home
Electrical Service

Figure 8
Wiring Diagram

Circuit
Breaker

L1

L2

To 240v
1 Phase
Power
supply

Electrical
Service ground

Ring Terminal
at Ground
Screw

Red

B

la

ck

Approved
Connectors

Water Heater

Smart Grid

Wire Harness

Bla

ck

Red

Green

Fire Hazard

Use 10 gauge solid copper wire.
Use a UL approved strain relief.
Connect ground wire to green

ground screw.
Failure to do so can result in

death, fire, or electrical shock.

WARNING

1. Check and turn off power to the electrical wiring of the

water heater before making any electrical connections

to the water heater.

2. Remove the junction box cover that is secured by one

screw (Figure 8A). Place the cover and screw aside

and view the wiring diagram. Locate the four power

wires inside the junction box (there will be TWO red

wires and TWO black wires).

3. Connect the electrical supply to the water heater in

accordance with the local utility requirements and

codes. A standard 1/2 inch opening has been made

in the junction box for the conduit connections (Fig-

ure 8A). NOTE: Use only 10 gauge solid copper wire

for the electrical connections and an appropriate size

double pole circuit breaker.

4.

Ground the water heater by connecting the bare cop-

per ground wire from the home’s electrical service to

the green ground screw (located on the electrical jun-

ction box on top of the water heater). See Figures 8

and 8A.

5. There are TWO black wires and TWO red wires in the

water heater. The smaller red and black wires are

used by the Smart Grid connector.