Whirlpool Energy Smart 188414 User Manual

Page 18

Advertising
background image

18

*These instructions are brief and intended as guidance for a qualifi ed person. If you lack the necessary

skills to perform these procedures call 1-877-817-6750 for assistance.

(ESM) ERROR CODE

INDICATES

CORRECTIVE ACTION*

E51

with an alert Icon flashing.

A failure to communicate with the Electronic
Thermostat (ET).

1. Turn off electrical power at the breaker, check all electrical connections,
and wiring for damage.
2. Replace the Electronic Thermostat (ET).
3. Turn on electrical power at breaker.

E52

with an alert Icon flashing.

Energy Smart

®

Module (ESM) is receiving the

wrong data from the Electronic Thermostat
(ET).

1. Turn off electrical power at the breaker, check all electrical connections,
and wiring for damage.
2. Replace the Energy Smart

®

Module (ESM), if this does not correct the

problem, also replace Electronic Thermostat (ET).

E71

with an alert Icon flashing.

Energy Smart

®

Module (ESM) thermistor

failure.

1. Turn off electrical power at the breaker, check all electrical connections,
and wiring for damage.
2. Turn on electrical power at breaker.
3. If error returns call service technician for assistance.

Advertising
This manual is related to the following products: