Warning – Wolf DUAL FUEL RANGES User Manual

Page 11

Advertising
background image

11

Leak testing of the appliance
shall be conducted according to
the following instructions:

Use a brush and liquid detergent to
test all gas connections for leaks.
Bubbles around connections will
indicate a leak. If a leak appears, shut
off gas valve controls and adjust con-
nections. Then check connections
again. Clean all the detergent solu-
tion from the range.

Put the burner heads on each

burner base. Place the burner grates
over the burner bases and heads.

SIDE PANEL

ANTI-TIP
BRACKET

BASE FLANGE

5

3

/

4

" min

TO FLOOR

WALL

FLOOR

Anti-tip Bracket Installation

WARNING

This range can tip. Injury to
persons could result. Install the
anti-tip device packed with this
range. Follow these installation
instructions.

A N T I - T I P B R A C K E T
I N S T A L L A T I O N

Raise the unit to its desired height

using the rear leveling casters and
adjusting the front adjustable legs.
Try fitting the unit in place to verify
the correct height.

Measure from the floor to the top

of the range base flange on the back
of the unit.

Add 1/8" to this dimension, and

mark this height on the wall behind
the unit. This will be the location of
the bottom edge of the anti-tip
bracket. Try to center the mark
between the cabinets. For 48-inch
and 60-inch ranges, care must be
taken to verify that the anti-tip
bracket does not interfere with the
inner cavity supports.

Locate a stud or other solid mount-

ing source, and install the anti-tip
bracket at the same level as this line.

Push the unit back, and ensure the

rear base flange fits under the anti-tip
bracket.

WARNING

Never test for a gas leak with a
match or other flame.

Advertising