Command Reference Guide

/C

Connect

Establishes a bi-directional connection between two ports. For more

information and command line examples, please refer to Section 8.1. There

are two types of port connections:

Resident Connect: If the /C command specifies one port name or

number, your resident port will be connected to the specified port.

Third Party Connect: If the /C command specifies two port names or

numbers, the unit will connect the two ports indicated. A Third Party

Connect command must be issued from a third port where Supervisor

Mode is active. Passwords and ports that do not permit Supervisor Mode

cannot initiate a Third Party Connect.

Note:

• Passwords and ports that do not permit Supervisor Mode can only

connect to the ports that are specifically allowed by the password

entered at log in.

• Passwords and ports that permit Supervisor Mode can connect to

any free APS-8M port.

Availability: Supervisor Mode / Non-Supervisor Mode
Format:

/C <x> [x] [Enter]

Where

x is the number or name of the port(s) to be connected.

Response:

Verbose: Connected

xx, when a Resident Connection is initiated, the APS

will also display the currently selected Resident Disconnect Sequence for

your port.

Terse: 1

/CP Copy RS232 Port Parameters

Allows quick set-up when all RS232 ports will be configured with the same or

similar parameters. When the /CP command is invoked, the APS will display

a menu that is used to select common port parameters, which can then be

copied to all APS RS232 ports. Note that the Copy Command will not change

restricted parameters at Ports 1, 2, and 8. For more information, please refer to

Section 5.6.
Availability: Supervisor Mode Only
Format:

/CP [Enter]

Response: Displays Copy Parameters Menu