Detailed Description

FPGA INIT and DONE LEDs

The typical Xilinx FPGA power up and configuration status LEDs are present on the SP605.

The red INIT LED DS17 comes on momentarily after the FPGA powers up and during its
internal power-on process. The DONE LED DS2 comes on after the FPGA programming
bitstream has been downloaded and the FPGA successfully configured.

X-Ref Target - Figure 1-14

Figure 1-14:

FPGA INIT and DONE LEDs

Table 1-22:

FPGA INIT and DONE LED Connections

U1 FPGA Pin

Schematic Net

Name

Controlled LED

Y4

FPGA_INIT_B

DS17 INIT, Red

AB21

FPGA_DONE

DS2 DONE, Green

VCC2V5

VCC2V5

VCC2V5

INIT_B = 0, LED: ON
INIT_B = 1, LED: OFF

1

2

R70
27.4

1/16W

1%

1

2

R169
332

1/16W

1%

2

1

D

S

2

LED-GRN-

S

MT

1

2

R69

75.0

1%

2

1

D

S

17

LED-RED-

S

MT

FPGA_INIT_B

2

1

5%
1/16W

4.7K

R19

FPGA_DONE

UG526_14 _092409