ZyXEL Communications XGS-4528F User Manual

Page 76

Advertising
background image

Chapter 7 Basic Setting

XGS-4528F User’s Guide

76

Contact Person's

Name

Type the name of the person in charge of this Switch. You can use up to 32

printable ASCII characters; spaces are allowed.

Use Time Server

when Bootup

Type the time service protocol that your timeserver uses. Not all time servers

support all protocols, so you may have to use trial and error to find a protocol that

works. The main differences between them are the time format.
When you select the Daytime (RFC 867) format, the Switch displays the day,

month, year and time with no time zone adjustment. When you use this format, it is

recommended that you use a Daytime timeserver within your geographical time

zone.
Time (RFC-868) format displays a 4-byte integer giving the total number of

seconds since 1970/1/1 at 0:0:0.
NTP (RFC-1305) is similar to Time (RFC-868).
None is the default value. Enter the time manually. Each time you turn on the

Switch, the time and date will be reset to 1970-1-1 0:0.

Time Server IP

Address

Type the IP address of your timeserver. The Switch searches for the timeserver for

up to 60 seconds. If you select a timeserver that is unreachable, then this screen

will appear locked for 60 seconds. Please wait.

Current Time

This field displays the time you open this menu (or refresh the menu).

New Time

(hh:min:ss)

Enter the new time in hour, minute and second format. The new time then appears

in the Current Time field after you click Apply.

Current Date

This field displays the date you open this menu.

New Date (yyyy-

mm-dd)

Enter the new date in year, month and day format. The new date then appears in

the Current Date field after you click Apply.

Time Zone

Select the time difference between UTC (Universal Time Coordinated, formerly

known as GMT, Greenwich Mean Time) and your time zone from the drop-down list

box.

Daylight Saving

Time

Daylight saving is a period from late spring to early fall when many countries set

their clocks ahead of normal local time by one hour to give more daytime light in the

evening.
Select this option if you use Daylight Saving Time.

Start Date

Configure the day and time when Daylight Saving Time starts if you selected

Daylight Saving Time. The time is displayed in the 24 hour format. Here are a

couple of examples:
Daylight Saving Time starts in most parts of the United States on the second

Sunday of March. Each time zone in the United States starts using Daylight Saving

Time at 2 A.M. local time. So in the United States you would select Second,

Sunday, March and 2:00.
Daylight Saving Time starts in the European Union on the last Sunday of March. All

of the time zones in the European Union start using Daylight Saving Time at the

same moment (1 A.M. GMT or UTC). So in the European Union you would select

Last, Sunday, March and the last field depends on your time zone. In Germany for

instance, you would select 2:00 because Germany's time zone is one hour ahead

of GMT or UTC (GMT+1).

Table 10 Basic Setting > General Setup (continued)