Extract, Chord sort – Yamaha EX5R User Manual

Page 233

Advertising
background image

Patter

n Mode

233

Events

Sets the type of event that will be reduced. When
“Control Change” is selected, a setting parameter
will be added, and the control number can be
designated there.

Settings: Pitch Bend, Control Change (Control numbers

range from 000~127), Ch After Touch (Channel
After Touch), PolyAfter Touch (Polyphonic
After Touch)

6. Extract

This job moves all instances of specific data from a
designated range of a sequence track to the same range
on a different sequence track. Following the operation,
the targeted events no longer exist in the source track.
If data already existed at the destination, the extracted
data and existing data are mixed.

You can also use this job to delete the specified event
data rather than move it. You can do this by setting the
extract destination track to “off.”

Track

Selects the track that will be extracted from (Extract
source) and the track that will be copied to (Extract
destination).

Settings:

Extract source: 1~8
Extract destination: 1~8, off (extracted data is deleted)

Measure

Sets the measure range (the beginning measure and
the end measure) where Extract is executed.

Settings: 01~16 (for the beginning measure and the end

measure)

Events

Sets the type of event that will be extracted.

When an event other than "Sys. Exclusive" is
selected, additional parameters for the event range
will be added, and you can designate the range.

Settings: Note, Program Change, Pitch Bend, Control

Change, Ch After Touch (Channel After Touch) ,
PolyAfterTouch (Polyphonic After Touch),
Sys.Exclusive(System Exclusive)

Event Range

Sets the range you want to extract the event. The
unit of the value differs depending on the selected
event.

Note: C–2~G8

Program Change, Control Change (Control number),

Ch After Touch, PolyAfterTouch: 0~127

Pitch Bend: –8192~+8192

7. Chord Sort

This job “sorts” chordal note events (simultaneous
note events) by order of pitch. The notes can be either
sorted from the highest pitch to the lowest or from the
lowest pitch to the highest. The chords within the
designated range of the specified sequence track can be
sorted. For example, if notes E3, C3, and G3 all begin at
the same time, the job arranges the order to C3, E3, G3
(if set to “up order”) to G3, E3, C3 (if set to “down
order”).

Track

Sets the track where Chord Sort will be executed.

Settings: 1~8

Measure

Sets the measure range (beginning measure to the
end measure) where Chord Sort is executed.

Settings: 01~16 (for the beginning measure and the end

measure)

Type

Sets the type of Chord Sort. When “up order” is
selected, chords are sorted from the lowest pitch to
the highest, while selecting “down order” will sort
from the highest pitch to the lowest.

Settings: up order, down order

Pattern/E/qx 5/21/98 11:44 AM Page 233

Advertising