TABLE 8: COOLING CAPACITIES FOR WR240 (ALTERNATE REHEAT MODE)

Air on Evaporator Coil

Temperature of Air on Condenser Coil

75°F

85°F

CFM

WB
(°F)

Total

Cap.

1

(MBH)

Total

2

Input

(kW)

Sensible Capacity (MBH)

*

Return Dry Bulb (°F)

Total

Cap.

1

(MBH)

Total

2

Input

(kW)

Sensible Capacity (MBH)

*

Return Dry Bulb (°F)

90

85

80

75

70

65

90

85

80

75

70

65

6000

67

100

15.9

20

18

16

14

12

10

94

16.6

13

12

11

9

8

7

62

93

15.1

44

42

40

38

36

35

86

15.9

30

29

27

26

25

23

57

83

15.1

50

48

46

45

43

41

77

15.8

34

33

32

30

29

28

7000

67

109

15.8

31

28

24

21

18

15

103

16.5

25

23

20

18

15

12

62

102

15.1

68

65

62

59

56

53

95

15.8

57

54

52

49

47

44

57

90

15.0

74

74

71

68

64

61

85

15.7

63

63

60

58

55

52

8000

67

119

15.7

42

37

33

29

24

20

112

16.4

38

34

30

26

22

18

62

110

15.0

92

88

83

79

75

70

103

15.8

84

80

76

72

69

65

57

98

14.9

98

98

95

91

86

82

93

15.7

93

93

89

85

81

77

8450

67

113

15.7

42

38

33

29

25

21

107

16.4

39

35

31

27

23

19

62

105

15.0

88

88

85

80

76

72

98

15.8

84

84

80

76

72

68

57

93

14.9

93

93

92

87

83

79

88

15.7

88

88

86

82

78

75

8900

67

107

15.7

42

38

34

30

26

22

101

16.4

40

36

32

29

25

21

62

99

14.9

88

88

86

82

78

73

93

15.8

84

84

83

79

75

71

57

88

14.9

88

88

88

84

80

76

84

15.7

84

84

84

80

76

72

95°F

105°F

6000

67

87

17.3

7

6

5

5

4

3

77

18.2

3

3

3

2

2

2

62

79

16.7

16

15

14

14

13

12

68

17.7

8

7

7

7

6

6

57

72

16.5

18

18

17

16

16

15

63

17.4

9

9

9

8

8

7

7000

67

96

17.2

20

18

16

14

12

10

86

18.2

15

14

12

11

9

7

62

88

16.6

46

44

42

40

38

35

76

17.7

36

35

33

32

30

28

57

79

16.4

53

52

50

48

46

44

70

17.4

43

43

41

40

38

36

8000

67

106

17.2

34

30

27

23

20

16

94

18.2

28

25

22

19

16

13

62

96

16.6

76

73

69

66

62

59

84

17.7

65

62

59

57

54

51

57

87

16.4

87

86

83

79

76

72

78

17.4

78

77

74

71

68

65

8450

67

101

17.2

36

32

29

25

22

18

90

18.1

29

26

23

20

17

14

62

92

16.6

78

78

75

71

68

64

80

17.6

68

66

63

60

57

54

57

83

16.4

83

83

81

77

74

70

74

17.3

74

74

72

69

67

64

8900

67

96

17.2

38

35

31

27

24

20

86

18.1

30

27

24

21

19

16

62

87

16.6

79

79

79

75

72

67

76

17.6

71

69

66

63

60

57

57

79

16.4

79

79

79

75

72

68

71

17.3

71

71

71

68

65

62

115°F

125°F

6000

67

67

19.1

-

-

-

-

-

-

57

20.0

-

-

-

-

-

-

62

57

18.7

-

-

-

-

-

-

46

19.7

-

-

-

-

-

-

57

54

18.3

-

-

-

-

-

-

46

19.2

-

-

-

-

-

-

7000

67

75

19.1

11

10

8

7

6

5

64

20.1

6

5

5

4

3

3

62

64

18.7

27

26

25

24

23

21

52

19.7

18

17

16

16

15

14

57

61

18.3

34

33

32

31

30

29

52

19.2

25

24

24

23

22

22

8000

67

83

19.2

21

19

17

15

13

10

72

20.1

15

14

12

11

9

7

62

71

18.7

54

52

50

47

45

43

58

19.8

43

41

40

38

37

35

57

68

18.3

68

67

65

62

60

58

58

19.3

58

57

56

54

52

51

8450

67

80

19.1

22

19

17

15

13

11

70

20.0

14

13

12

10

9

7

62

68

18.6

55

53

51

48

46

44

56

19.7

41

40

38

37

36

34

57

65

18.2

65

65

64

61

59

57

56

19.2

56

56

55

54

52

51

8900

67

77

19.0

22

20

18

16

14

12

67

19.9

13

12

11

10

9

7

62

65

18.5

55

53

51

49

47

45

54

19.5

40

38

37

36

35

33

57

63

18.2

63

63

63

61

59

56

54

19.0

54

54

54

53

52

51

1. The capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower

Performance table for the kW of the supply air blower motor.

2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

All Sensible Capacity