Adjust the reflective sensor – Zebra Technologies Z4Mplus User Manual
Page 69

61
Operations
Position the Media Sensors
1/18/06
Z4Mplus/Z6Mplus User Guide
13163L-001 Rev. A
Adjust the Reflective Sensor
The reflective sensor is compatible with most types of media. With non-continuous media, the
reflective sensor detects the start-of-label indicator (the notch, hole, black mark, or gap
between die-cut labels). With both continuous media and non-continuous media, the sensor
detects an out-of-paper condition. If you have difficulties with calibration while using this
sensor, use the transmissive sensor (see
Select or Position the Transmissive Sensor
).
Position the reflective sensor in the following way:
• directly under the notch, hole, or black mark with these types of labels
• anywhere along the width of the media if there is a gap between labels
• anywhere under the media for continuous media
The glow of the red light through the media may help you accurately position the sensor.
Figure 24 • Adjusting the Reflective Sensor
1
Printhead assembly
2
Reflective sensor
3
Reflective sensor positioning lever
4
Printhead release latch
1
2
3
4