ZyXEL Communications G.SHDSL.bis 4-port Security Gateway P-793H User Manual

Page 92

Advertising
background image

P-793H User’s Guide

92

Chapter 5 WAN Setup

Figure 32 WAN > WAN Backup Setup > Advanced Setup > Edit

The following table describes the labels in this screen.

Table 22 WAN > WAN Backup Setup > Advanced Setup > Edit

LABEL

DESCRIPTION

AT Command

Strings

Dial

Enter the AT Command string to make a call.

Drop

Enter the AT Command string to drop a call. “~” represents a one second wait, e.g.,

“~~~+++~~ath” can be used if your modem has a slow response time.

Answer

Enter the AT Command string to answer a call.

Drop DTR When

Hang Up

Select this if you want the DTR (Data Terminal Ready) signal to be dropped after

the Drop string is sent out.

AT Response

Strings

CLID

Enter the keyword that precedes the CLID (Calling Line Identification) in the AT

response string. This lets the ZyXEL Device capture the CLID in the AT response

string that comes from the WAN device. CLID is required for CLID authentication.

Called ID

Enter the keyword preceding the dialed number.

Speed

Enter the keyword preceding the connection speed.

Call Control

Dial Timeout

Enter a number of seconds for the ZyXEL Device to keep trying to set up an

outgoing call before timing out (stopping). The ZyXEL Device times out and stops if

it cannot set up an outgoing call within the timeout value.

Retry Count

Enter a number of times for the ZyXEL Device to retry a busy or no-answer phone

number before blacklisting the number.

Retry Interval

Enter a number of seconds for the ZyXEL Device to wait before trying another call

after a call has failed. This applies before a phone number is blacklisted.

Drop Timeout

Enter a number of seconds for the ZyXEL Device to wait before dropping the DTR

signal if it does not receive a positive disconnect confirmation.