Master/Slave Configuration

The Master/Slave system can be configured through the Xantrex Solar
GUI (Graphical User Interface) software, P/N 1-152577-01, or through
the Operator Interface Panel.

Establish remote or local communication with the GT100E, using the
Xantrex Solar GUI software.

To set a unit up as the Master Unit:

1. Click Tools > Inverter Data > Operational Configuration

2. Check the Configured Master check box

3. Click Send Configuration

4. Verify that the Present Inverter Data has the unit set as the Configured

Master unit.

Important:

If the inverter's date (not the workstation's!) is odd then the

Inverter is OPERATIONAL MASTER until midnight; if the inverter's date is
even, the Inverter is OPERATIONAL SLAVE until midnight.