Designing Your Installation

3–7

Calculating Size of DC Input Cables for XPower 1200 Plus

Refer to

Table 3-1

to plan the DC input cabling for your particular

application:

Keep all cables as short as possible, and ensure that each cable
between the inverter and the battery is no longer than 5 feet (1.5 m).

Do not use aluminum cable. It has about 1/3 more resistance than
copper cable of the same size, and it is difficult to make good, low-
resistance connections to aluminum wire.

Xantrex recommends that you use oil resistant cable.

Table 3-1 Recommended DC Input Wire Sizes & Lengths: XPower
1200 Plus

RV

1

(Recreational Vehicle) and Marine

2

1. Based on US National Electrical Code NFPA70, Article 551 and Table 310-
17, 90C cables located outside of engine spaces.

2. Based on ABYC (American Boat and Yacht Council) Recommended Practice
E-9, Table IV, 75C cables located outside of engine spaces, maximum 3% volt-
age drop.

Cable length:
Battery to inverter
(one way)

Minimum Cable Size

Maximum Battery
Fuse Size

2 feet (0.6 m)

No. 2 AWG

150 Adc

4 feet (1.2 m)

No. 2 AWG

150 Adc

5 feet (1.5 m)

No. 2 AWG

150 Adc

Note: Never use a cable longer than 5 feet (1.5 m) with the XPower
1200 Plus. Appropriately sized cable can be bought at a welding supply
house or a marine supply store.