Designing Your Installation

3–11

Calculating Size of Chassis Ground Cable for XPower 1750 Plus

Refer to

Table 3-4

to plan the size of the chassis ground cable that runs

from the grounding point to the chassis ground screw on the inverter’s DC
panel.

Table 3-4 Recommended Chassis Ground Cable sizes: XPower 1750
Plus

Application

Chassis ground cable size
(Stranded cable is
recommended)

Maximum
Battery
Fuse Size

Recreational Vehicle

1

1. Based on US National Electrical Code NFPA70, Article 551, par. 551-20c.

No. 8 AWG

250 Adc

Marine

2

2. Based on ABYC (American Boat and Yacht Council) Recommended Practice
E-9, par. 9.21.

The same size as the DC input
cables or one size smaller.

250 Adc

Note: There are no restrictions on length for the chassis ground cable.