Xantrex Technology 1200 User Manual

Page 31

Advertising
background image

Installation

3–8

Calculating Size of Chassis Ground Cable for XPower 1200 Plus

Refer to Table 3-2 to plan the size of the chassis ground cable that runs
from the grounding point to the chassis ground screw on the inverter’s DC
panel.

Table 3-2 Recommended Chassis Ground Cable sizes: XPower 1200

Plus

Application

Chassis ground cable size
(Stranded cable is
recommended)

Maximum
Battery
Fuse Size

Recreational Vehicle

1

1. Based on US National Electrical Code NFPA70, Article 551, par. 551-20c.

No. 8 AWG

150 Adc

Marine

2

2. Based on ABYC (American Boat and Yacht Council) Recommended Practice
E-9, par. 9.21. (The actual size required is minimum No. 5 AWG, but since odd
sizes are hard to find, No. 4 AWG is specified.)

The same size as the DC input
cables or one size smaller.

150 Adc

Note: There are no restrictions on length for the chassis ground cable.