Inverter loads – Xantrex Technology 1200 User Manual

Page 49

Advertising
background image

Operation

4–4

Input Voltage

The allowable XPower Plus input voltage ranges are shown in the
following table:

Inverter Loads

The XPower Plus will operate most AC loads within its power rating:
1000 watts for the XPower 1200 Plus and 1500 watts for the XPower
1750 Plus. However, some appliances and equipment may be difficult to
operate, and other appliances may actually be damaged if you try to
operate them with the XPower Plus. Please read

“High Surge Loads”

and

“Trouble Loads”

carefully.

High Surge Loads

Some induction motors used in freezers, pumps, and other motor-operated
equipment require high surge currents to start. The XPower Plus may not
be able to start some of these motors even though their rated current draw
is within the inverter’s limits. The XPower Plus will normally start single-
phase induction motors rated at 1/2 horsepower or less.

If a motor refuses to start, observe the

INPUT VOLTAGE DISPLAY

while

trying to start the motor. If the indicator drops below 11 volts while the
XPower Plus is trying to start the motor, this low voltage condition may

Operating
Condition

Voltage Range Comment

Normal

10 V–15 V

Optimum
Performance

12 V–13 V

Low Voltage Alarm

10.7 V or less

The audible low battery alarm sounds.

Low Voltage
Shutdown

less than 10 V

The inverter shuts down to protect the
battery from being over-discharged.

High Voltage
Shutdown

15 V or more

The inverter shuts down to protect
itself from excessive input voltage.
Note: Although the XPower Plus
incorporates over-voltage protection,
it can still be damaged if input voltage
exceeds 16 V.