Designing Your Installation
3–9
Calculating Cable Sizes for XPower 1750 Plus
To operate safely and effectively, the XPower 1750 Plus needs proper 
cables and fuses. Because the XPower 1750 Plus has low-voltage and 
high-current input, it is essential that you use low-resistance wiring 
between the battery and the inverter to deliver the maximum amount of 
usable energy to your load.
For safe and efficient operation, you will need to calculate cable sizes for 
your:
•
DC input cables from the battery to inverter (one way)
•
Chassis ground cable from the grounding point to the chassis ground 
screw on the inverter’s DC panel.
See
“DC Panel Connections (XPower 1750 Plus shown)”
Figure 3-3 on
page 3–17
.
WARNING: Fire Hazard
Never use a cable longer than 6 feet (1.8 meters). A cable 
longer than 6 feet (1.8 meters) can potentially generate enough 
heat to start a fire or result in poor inverter performance.