Nomenclature, Johnson controls unitary products 9 – York Y33 User Manual

Page 9

Advertising
background image

246653-YTG-E-0108

Johnson Controls Unitary Products

9

NOMENCLATURE

12

3

4

CONTROL

ADDITIONAL

D = SYNTHESYS CONTROL

CONFIGURATION

VOLTAGE

E = SYNTHESYS CONTROL,

OPTIONS

2 = 208/230-60

DISC., 110V OUTLET

Cu/Cu Condenser Coil

3 = 380-60

F = SYNTHESYS, DISC.

Cu/Cu Evaporator Coil

4 = 460-60

Exhaust VFD (Custom

e

r)

5 = 575-60

H = SIMPLICITY CONTROL

(see notes 3 & 7)

7 = 380/415-50

I = SIMPLICITY CONTROL, DISC

NOTES:

110V OUTLET

1.

108KW not available with 208/230V.

J = SIMPLICITY CONTROL,

* Premium Cabinet (6 doors)

2.

Standard efficiency

motor meets Canadian

DISC, NO 110V OUTLET

* Standard Cabinet (4 doors)

ID BLOW

ER

(See note 4)

minimum efficiency

regulations mandated

K = SIMPLICITY CONTROL W

/MODLINC

* Drain Pan - powder coat

A = a, f, i

L

= d, g, j

W

= d, e, j

in Canadian Energy

Efficiency

Regulations.

L = SIMPLICITY CONTROL W

/ MODLINC

* Drain Pan - stainless steel

B = a, g, i

M

= b, f, i

X

= d, f, h

3.

(VFD-CUSTOMER) = Wired for VFD

DISC, 110V OUTLET

C = a, f, j

N

= b, f, j

Y

= b, e, h

only

; VFD will be custom

er supplied and

M = SIMPLICITY CONTROL W

/MODLINC

*

must

m

a

ke selections

D = a, g, j

O

= b, g, i

Z

= b, e, i

field installed. If VFD Exh is also

DISC, NO 110V OUTLET

N = YCCS CONTROL

P = YCCS CONTROL W/DISC., 110V OUTLET

Q = YCCS ZONING CONTROL

R = YCCS ZONING CONTROL W/DISC.,

110V OUTLET

S = YCCS - VAV CONTROL

T = YCCS - VAV CONTROL W/DISC.,

110V OUTLET

in these options

E = a, e, h

P

= b, g, j

2

= b, e, j

specified, it will also be cust supplied.

F = a, e, i

Q

= c, f, i

3

= b, f, h

4.

VAV ID Blower requires hot gas by

pass .

G = a, e, j

R

= c, f, j

4

= c, e, h

5.

Power exhaust and barometric relief not

H = a, f, h

S

= c, g, i

6

= c, e, i

available in end return configuration.

CONFIGURATION

I = d, f, i

T

= c, g, j

7

= c, e, j

6.

Air foil fan available on cooling only

.

A = 1,2

1 - BOTTOM RETURN

J = d, f, j

U

= d, e, h

8

= c, f, h

9 = d, g, h

Contact engineering for

B = 1,4

2 - BOTTOM SUPPLY

K = d, g, i

V

= d, e, i

air foil applications.

C = 1,5

3 - END RETURN

(5

)

Air Volum

e

7.

Only

available with Hi EFF m

o

tors

ECONOMIZER

D = 3,2

4 - REAR SUPPLY

a = CV

A = DUAL ENTH Low leak type

E = 3,4

5 - FRONT SUPPLY

b = VAV (VFD-FACTORY INSTALLED)

B = SINGLE ENTH Low leak type

F = 3,5

c = BYPASS FACTORY VFD

C = DRY BULB ENTH Low leak type

FRONT SUPPLY - COOLING ONLY

d = VAV (VFD-CUSTOMER)

(3)

D = MANUAL Low leak (Not w/PE)

HOT WATER

, STEAM

& ELECTRIC HEAT -

Fan (See note 6)

E = NONE

BOTTOM SUPPLY ONLY

e = FORW

ARD CURVE FAN Class I

B = 2,3,5,7

M

= 1,3,6,8

X

= 2,4,0,7

F = DUAL ENTH Std type

GAS HEAT - BOTTOM OR REAR SUPPLY ONLY

f = FORW

ARD CURVE FAN Class II

C = 1,4,5,7

N

= 2,3,6,8

Y

= 1,3,9,8

G = SINGLE ENTH Std type

g = AIR FOIL FAN [always Class II]

D = 2,4,5,7

O

= 1,4,6,8

Z

= 2,3,9,8

H = DRY BULB Std type

HEAT SOURCE

E = 1,3,6,7

P

= 2,4,6,8

2

= 2,4,9,8

N = NATURAL GAS

Blower Mount

F = 2,3,6,7

Q

= 1,3,9,7

3

= 1,3,0,8

S = NATURAL GAS, SS HEAT EXCHANGER

h = Neoprene

G = 1,4,6,7

R

= 2,3,9,7

4

= 2,3,0,8

EXHAUST

(S

ee note 5)

D = NATURAL GAS, MODULATING HEAT*

i = 1 inch deflection spring

H = 2,4,6,7

S

= 1,4,9,7

5

= 1,4,0,8

A = BARO

J = 2, 5

S

= A, 3

T = NATURAL GAS, MODULATING HEAT, SS *

j = 2 inch deflection spring

I = 1,3,5,8

T

= 2,4,9,7

6

= 2,4,0,8

B = 1, 3

K

= 2, 6

T

= A, 4

HEAT EXCHANGE

R

J = 2,3,5,8

U

= 1,3,0,7

7

= 1,4,9,8

C = 1, 4

L

= 2, 7

U

= A, 5

E = ELECTRIC HEAT

K = 1,4,5,8

V

= 2,3,0,7

D = 1, 5

M

= 2, 8

V

= A, 6

C = COOLING ONLY

9 = Non-Std

E = 1, 6

N

= NONE

W

= A, 7

W

= HOT W

A

TER COIL

ID MOTOR

(See note 2)

F = 1, 7

O

= 1, 9

X

= A, 8

X = STEAM COIL

1 = 10 HP STD

Condenser Coil

Head Press. Ctrl.

G = 1, 8

P

= 1, 0

Y

= A, 9

2 = 15 HP STD

1 = STANDARD

7 = YES

H = 2, 3

Q

= 2, 9

Z

= A, 0

3 = 20 HP STD

2 = TECHNICOAT

8 = NO

I = 2, 4

R

= 2, 0

2

= 8,000 CFM ERV

HEAT CAPACITY

4 = 25 HP STD (Except 25T)

Piping

(See note 4)

3 = 13,000 CFM ERV

3 = 267 MBH

5 = 10 HI-EFF

3 = STANDARD 4 = HOT GAS BYPASS

5 = 533 MBH

6 = 15 HI-EFF

Evaporator Coil

9 = Non Std Config

8 = 800 MBH (40T ONLY)

7 = 20 HI-EFF

5 = STANDARD

Power Exhaust

4 = 40 KW

8 = 25 HI-EFF (Except 25T)

6 = HI-CAP (30T/40T R22 ONLY)

1 = MODULATING DAMPERS

A = VFD MODULATING

MOTOR

8 = 80 KW

9 = 7.5 HP STD (25T Only)

9 = STD W

/TECHNICOAT

2 = NON-MOD. (ON/OFF)

1 = 108 KW

(1)

0 = 7.5 HI-EFF (25T Only)

0 = HI-CAP W

/T-COAT (30T/40T R22)

0 (ZERO) NO HEAT

Motor

1 = 1 ROW

0 = 5 HP HI-EFF (25T Only)

9 = 5 HP (25T Only)

2 = 2 ROW

3 = 7.5 HP

6 = 7.5 HP HI-EFF

1 = 1 ROW

4 = 10 HP

7 = 10 HP HI-EFF

5 = 15 HP (Except 25 Ton)

8 = 15 HP HI-EFF (Except 25 Ton)

Config

A

13

D

14

W

= 1,4,0,7

3

3

N

5

A

4

PACKAGE

3

6

4

7

FILTERS

C

12

B

8

1

9

A

10

A

11

GENERATION

3

2

Y

1

Y = York Brand R22

A = STAND.

B = 65%

C = 95%

D = 2" HI-EFF

A = 1,3,5,7

REFRIGERATION

(30T/40T)

3 = 30 TON

4 = 40 TON

2 = 25 TON

L = 2,4,5,8

BASIC UNIT

Class I blower is limited to 15HP in 25/30Ton

Class I blower is limited to 20HP in 40Ton

Class II blowers are not HP limited