IES-5000/5005/6000 Support Notes

30

In this network application, we will use an IES-5000, a ZyXEL ES-2024

VLAN-aware switch and Prestige 660R-61 CPE (you may also use P791 if you have

the SLC-1248G line card installed on the IES).

1. IES-5000 Settings

1.1 VLAN setup

Follow the procedure as described in the VLAN Application section to configure the

VLAN settings on the IES-5000.

Create a VLAN with a VID of 10 and set Port 1 and ENET 1 to be members of this

VLAN. Also enable egress tagging on ENET 1.

TGE1> vlan name 10 VLAN10

TGE1> vlan set 10 up1 fix tag

TGE1> port pvc vlan 7-1-0/33 10 join untag

Create a VLAN with a VID of 20 and set Port 1 and ENET 1 to be members of this

VLAN. Also enable egress tagging on ENET 1.

TGE1> vlan name 20 VLAN20

TGE1> vlan set 20 up1 fix tag

TGE1> port pvc vlan 7-1-0/33 20 join untag

1.2 VC profile setup

For profile setup, create a Defval_CBR VC profile with the Encap, Class, PCR and

CDVT settings as shown. Make sure the profile has the same LLC-based

encapsulation setting as the IES-500 and the CBR class is set with a higher ATM QoS

priority .

CI command

TGE1> profile atm set Def_CBR cbr 300000

1.3 Multiple PVCs setup