Installation diagram, Dc connections – Xantrex Technology AGS User Manual

Page 10

Advertising
background image

10

START

START COMMON

POSITIVE POWER (+)

BATT SENSE POSITIVE(+)

NEGATIVE POWER/SENSE(-)

THERMOSTAT 1

THERMOSTAT 2

THERMOSTAT 1, 3 COMMON

THERMOSTAT 2 COMMON

DC CONNECTIONS

16 pin Connector

STOP

GEN HOUR METER

8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9

PREHEAT

PREHEAT

STOP COMMON

THERMOSTAT 3

INSTALLATION NOTE:
It is advised to interlock the AGS system so that the
AGS unit is turned off when the coach is in motion.
This may be done by removing power from the AGS
Controller. To accomplish this the AGS Controller
should be interlocked with the ignition switch to
control the POSITIVE POWER (#5) or with the parking
brake to disconnect POWER/SENSE NEGATIVE (#13).

Connector view is looking into the AGS CONTROLLER.
All wires should be #18 AWG
MATING CONNECTORS:
Xantrex P/N 76-0090-01 (mating connector and harness) is
recommended for easy installation.
Note: Connector below matches both AMP and MOLEX
connectors, but pin numbers only match AMP connector.

AMP: 770583-1, PINS 770988-1

INSTALLATION DIAGRAM

RESERVED

(FOR IGN. LOCK-OUT)