Operation – Xantrex Technology AGS User Manual

Page 6

Advertising
background image

6

OPERATION

When it is off, the OFF light is illuminated.
DEFAULT: OFF mode.
AUTO Mode
In AUTO mode, the Control Module will respond to requests for
generator start from a low battery condition or from an air condi-
tioning demand.
AUTO QUIET Mode
In AUTO QUIET mode (both lights on at the same time) the Control
Module will respond to requests from low battery or air condition-
ing because the time is outside of the user-set Quiet Time. In
AUTO QUIET mode (AUTO light on and QUIET light blinking) the
AGS will not respond to requests for low battery or thermostats
starting because the Local Time is within the

Quiet Time window.

ON/OFF MODE Switch

Pressing the ON/OFF switch changes the status of
the AGS from OFF to AUTO to AUTO QUIET mode.

GEN ON Light

The GEN ON light is on whenever the generator is running. This
includes when the auxiliary generator is run manually.
DEFAULT: Light OFF

GEN FAULT Light
The generator has failed to start or has stopped during AGS
control. This will happen if the generator is manually stopped by a
generator start/stop switch that is independent of the AGS. Cy-
cling the ON/OFF switch will clear the fault. Check generator for
normal operation.
DEFAULT: OFF

On/Off