Common questions, Parameter values – Xantrex Technology AGS User Manual

Page 12

Advertising
background image

12

COMMON QUESTIONS

Why is the display blank except for the mode lights?
If buttons are not pressed within five seconds, the Remote Panel
goes into a sleep mode to conserve energy.

Why is action not immediate?
The Remote Panel waits 15 seconds to determine if any more
changes are to be made. At the end of this period, the display
goes to sleep and actions previously entered take effect.

When the On/OFF is moved to OFF position, the generator
does not stop immediately.
The action from the buttons on the Remote Panel is delayed to
ensure that action is required.

How long is the delay from request for thermostat request to
generator start?
The time delay is 60 seconds.

What is the low battery set point and how long does the
battery voltage have to stay there to initiate a generator start?
The Low Battery set point is around 11.5 VDC. The battery voltage
must stay at or below 11.5 volts for approximately 15 seconds
before the AGS will start the generator.

PARAMETER VALUES

Low battery voltage set point

11.5 VDC

Run time for generator

2 hours

Maximum generator run time

4 hours

Number of generator start tries

3 times

Advertising