Installation instructions, Removal of the log guard – Yeoman YM-CL8HB User Manual

Page 23

Advertising
background image

23

INSTALLATION INSTRUCTIONS

—Secure with self tapping screw.

—Seal the connecting joints.

Do not use a 90˚elbow to make this connection.

The flue must be installed in accordance with manufacturers

instructions.

PR8735

Seal Collar with Fire Cement

Self tapping screw

Tee

Size

Stovax Part No.

6"

4616

Cap

PR8736

600mm min

1000mm max

unsupported

Elbow with access cover

Size

Stovax Part No.

6"

4612

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

To chimney connection

as detailed in building

regulations

2. REMOVAL OF THE LOG GUARD

2.1 To remove the Log guard:

—Lift Log Guard clear of the supporting brackets.

—Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

PR8009

The flue must be installed in accordance with

manufacturers instructions.

PR8733

Self tapping

screw at rear

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

Seal flue collar

with Fire Cement

600mm min

1000mm max

unsupported

Elbow with access cover

Size

Stovax Part No.

6"

4612

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

To chimney connection

as detailed in building

regulations

PR8734

1.3 Rear flue pipe installation:

—Insert a tee into the flue collar. The tee piece is used as

cleaning access.

—Lift appliance into position, taking care not to damage

the hearth finish.

Level using adjustable bolts.

—Connect tee to the chimney using flue pipe.

Advertising