USER INSTRUCTIONS

WARNING

Properly installed, operated and maintained this

appliance will not emit fumes into the room.

Occasional fumes from de-ashing and refuelling may occur.

Persistent fume emission is potentially dangerous and

must not be tolerated.

If fume emission does persist:

—Open doors and windows to ventilate the room.

—Allow fire to burn out and safely dispose of fuel from the

appliance.

—Check for chimney blockage and clean if required.

—Do not attempt to relight until the cause of the emission

has been identified and corrected. If necessary seek

expert advice.

All open flued appliances can be affected by temporary

atmospheric conditions which may allow fumes to enter

the house. Because of this it is recommended that an

electronic carbon monoxide detector conforming to

BSEN50291 be fitted and maintained.

2. USING THE APPLIANCE FOR THE FIRST

TIME

2.1 To allow the appliance to settle and fixing glues and paint

to fully cure:

Operate the appliance at a low temperature for first

few days.

2.2 Do not touch the paint during the first period of use.

2.3 During this time the appliance may give off some

unpleasant odours:

Keep the room well ventilated to avoid a build-up of

fumes.

CONDENSATION

CAUTION WHEN FILLING

2.4 When filling the boiler with water for the first time,

the cold water entering the water jacket can cause

condensation to form on the surfaces of the appliance

(inside and outside).

2.5 In certain conditions this condensation could result in a

considerable amount of water, in some cases enough to fill

the bottom of the appliance. This could be even worse if

the house has recently been re-decorated, wet plastered

or any other work has been undertaken which could result

in high humidity.

2.6 Precautions must be taken to ensure that this build up of

condensate does not overflow from the appliance onto

any surrounding fabric of the room e.g. carpets.

NOTE - THIS CONDENSATION IS NORMAL DURING

FILLING AND DOES NOT INDICATE A FAULTY OR

LEAKING STOV

E.

NORMAL RUNNING

2.7 During normal running this condensation should be

minimal if the system is fitted with the low limit thermostat

as detailed in 1.22 (above). This low limit thermostat

prevents the system pump from running until the stove has

reached temperature.

SEASONAL USE

2.8 If this appliance is unused for lengthy periods of

time it should be periodically checked to ensure that

condensation is not building up within the stove.

NOTE – THIS CONDENSATION IS NORMAL AND DOES

NOT INDICATE A FAULTY OR LEAKING STOVE

.

If the stove is going to be unused for very long periods of

time it is recommended to drain the system.

3. RECOMMENDED FUELS

3.1 Wood Logs

Burn only seasoned timber with a moisture content of less

than 20%. To ensure this allow cut wood to dry for 12 to

18 months.

Wood Length

3

Appliance

Wood Length

CL8

400mm

Poor quality timber:

—Causes low combustion efficiency.

—Produces harmful condensation.

—Reduces effectiveness of the airwash and life of the

appliance.

Do not burn construction timber, painted, impregnated

/ treated wood, manufactured board products or pallet

wood

.

Advertising