USER INSTRUCTIONS

5. RUNNING THE APPLIANCE

BURNING WOOD:

5.1 This appliance gives out its heat in two ways:

Directly into the room in which it is fitted through

convection and radiation.

Hot water to heat radiators and domestic hot water.

The output to hot water varies depending on how

quickly the fuel is being burnt. Fore more detail see the

graph on page 13.

5.2 Only for use with recommended fuels, see Section 3 for

full details.

Close the Primary Air control and use the Airwash to

control the burn rate when the appliance is at optimum

operating temperature (see Diagrams 7 & 8).

7

PR8012

8

PR8937

Airwash: Adjust

Wood burns best on a bed of ash (approx. 25mm (1")

deep).

Rake the embers evenly over the firebed and open the

Airwash control fully for a few minutes before

re-fuelling.

Do not refuel when a large amount of flames are

present in the firebox as this could cause smoke or

flames to spill into the room.

Close the doors immediately after refuelling.

5.3 Burn new logs at a high temperature for a few minutes

before adjusting the Airwash control. Refuel little and

often for clean, efficient burning.

Do not load above the log guard or base of baffle.

5.4 Do not burn large amounts of fuel with the Airwash

control closed for long periods of time. This reduces the

glass cleaning effect of the Airwash and causes tars and

creosotes to build-up in the appliance and flue system.

5.5 When in use, running the appliance at a high temperature

for a short period reduces tars and creosotes.

5.6 Experience establishes settings to suit personal preference.

Do not burn construction timber, painted,

impregnated / treated wood, manufactured board

products or pallet wood.

5.6 BURNING SOLID FUEL

To burn smokeless fuels a cast iron multi-fuel grate must

be fitted.

Only for use with recommended fuels (see User

Instructions, Section 3).

5.7 Set air controls as shown in Diagram 9.

9