If the Copy operation will cause a range change to Output 2, and if Output 2 is ON, the Output 2
ON/OFF key also flashes and the output is turned OFF when OK is pressed; the output can also
be turned off directly with its ON/OFF key before OK is pressed.

Auxiliary Output

The AUXILIARY output can provide up to 1 Amp at 2.7V, 3.3V or 5.0V. The output voltage is set
by a front-panel slide-switch and the current limit is fixed at

≥1Amp. The output terminals are

duplicated on the rear panel (screwless terminals) for rack use; there is no remote sense
capability. The output is switched On and Off electronically by the front panel switch or via one of
the remote control interfaces; no other function can be remote controlled on this output. Current
Limit is indicated when the output voltage has dropped by ~100mV; at this point the output will
typically source 1.5A and will maintain this current as the load impedance is reduced to a short-
circuit. If a short-circuit is maintained the output will eventually enter thermal shutdown.

26