Environmental factors – Xerox Nuvera 120 EA User Manual

Page 13

Advertising
background image

Xerox Nuvera

®

100/120/144 EA Digital Production System - Customer Expectations Document

- 13 -

Environmental Factors

Environmental Factor

Minimum

Maximum

Temperature

50

o

F (10

o

C)

(Tested to 60

° F (15.6

o

C))

87

o

F (30.6

o

C)

(Tested to 80

° F (26.7

o

C))

Humidity

15% RH

(Tested to 15%)

85% RH

(Tested to 80%)

Heat Emission (approximate)
(SFM / Scanner, Printer Module, MFF Professional)

2,322 BTU / HR

(Standby)

18,715 BTU / HR

(Running)

Heat Emission (approximate)

(SFM, Printer Module, BFM)

2,452 BTU / HR

(Standby)

19,023 BTU / HR

(Running)

Power Consumption (approximate)

(SFM / Scanner, Printer Module, MFF Professional)

0.680 kw

(Standby)

5,480 kw

(Running)

Power Consumption (approximate)
(SFM, Printer Module, BFM)

0.718 kw

(Standby)

5,570 kw

(Running)

SFM / PM / MFF Professional

6.2 B - Standby

8.6 B - Running

SFM / PM / BFM

6.6 B - Standby

9.0 B - Maximum

SFM / PM / FTM

7.2 B - Standby

9.0 B - Running

Noise

(Measured per ISO
7779 and declared
in Bel per ISO
9296)

SFM / PM / FTM / DS5000

7.2 B - Standby

9.1 B - Running

Altitude (above sea level)

0

10,000 ft.

Advertising