Operation settings, Settings, Cleaning, care and maintenance – STIEBEL ELTRON SHW 200-400 ACE с 06.05.2013 User Manual

Page 16: Troubleshooting

Advertising
background image

OPERAtIOn

Settings

16

| SHW ACE www.stiebel-eltron.com

4. settings

The temperature is infinitely adjustable. Depending upon the sys-

tem, the temperatures may vary from the set value.

26

�0

2�

09

�0

06

8�

1

2

1 Thermometer

2 Temperature selector

• Cold (frost protection)

i Low temperature setting, 35 °C

e Recommended energy saving position,

low scaling, approx. 60 °C

iii Maximum temperature setting, 82 °C
Temperature selection is limited in the delivered condition. This

limitation can be cancelled by a qualified contractor (see chapter

"Installation / Settings").

5. cleaning, care and maintenance

f

f Have the electrical safety of the appliance and the func-

tion of the safety assembly regularly checked by a heating

contractor.

f

f Never use abrasive or corrosive cleaning agents. A damp

cloth is sufficient for cleaning the appliance.

signal anode with consumption indicator

!

Material damage

If the consumption indicator changes colour from white

to red, have the signal anode checked by a heating con-

tractor and if necessary replaced.

2

3

1

26

�0

2�

09

�0

06

1

1 Signal anode with consumption indicator

2 White = anode OK

3 Red = ask your heating contractor to check

scaling
Almost every type of water deposits lime at high temperatures.

This settles inside the appliance and affects both the performance

and service life. The heating elements must therefore be descaled

from time to time. A qualified contractor who knows the local

water quality will tell you when the next service is due.

f

f Check the taps/valves regularly. You can remove limescale

deposits at the tap outlets using commercially available des-

caling agents.

f

f Regularly activate the safety valve to prevent it from becom-

ing blocked e.g. by limescale deposits.

6. troubleshooting

Fault

Cause

Remedy

The water does not heat

up.

There is no power.

Check the fuses/MCBs in

your fuse box.

The flow rate is low.

The aerator in the tap or

shower head is scaled up

or contaminated.

Clean and/or descale the

aerator or shower head.

If you cannot remedy the fault, notify your heating contractor. To

facilitate and speed up your enquiry, please provide the serial

number from the type plate (no. 000000-0000-000000):

Nr.: 000000 - 0000 - 000000

26

�0

2�

09

�0

05

7

Advertising