InStAllAtIOn

Installation

10.2 thermometer

D

00000

35

86

9

f

f Insert the thermometer as far as it will go and align it.

10.3 signal anode

!

Material damage

The appliance must not be operated without a consump-

tion indicator or with a damaged one, otherwise water

will leak out once the anode is depleted.

D

00000

35

87

1

1

2

1 Transport protection

2 Signal anode with consumption indicator

f

f Remove the transport protection.

f

f Check the consumption indicator for transport damage.

10.4 water connection and safety assembly

10.4.1 safety instructions

Note

Carry out all water connection and installation work in

accordance with regulations.

!

Material damage

When using plastic pipework, observe chapter "Specifi-

cation / Fault conditions".

!

Material damage

Operate the appliance only with pressure-tested taps.

cold water line
Galvanised steel, stainless steel, copper and plastic are approved

materials.

A safety valve is required.

dHw line
Stainless steel, copper and plastic pipework are approved ma-

terials.

10.4.2 connection

f

f Flush the pipes thoroughly.
The max. permissible pressure must not be exceeded (see chapter

“Specification / Data table”).
ff

Install a type-tested safety valve in the cold water supply

line. Please note that, depending on the static pressure, you

may also need a pressure reducing valve.

f

f Fit the DHW outlet pipe and the cold water inlet pipe.
ff

Size the drain so that water can drain off unimpeded when

the safety valve is fully opened.

ff

Fit the discharge pipe of the safety valve with a constant

downward slope and in a room free from the risk of frost.

ff

The safety valve discharge aperture must remain open to the

atmosphere.