SHW ACE |

19

InStAllAtIOn

Commissioning

10.5 Power supply

WARNING Electrocution

Before any work on the appliance, disconnect all poles

from the power supply.

WARNING Electrocution

The connection to the power supply is only permissible

as a permanent connection in conjunction with the re-

movable cable entry. Ensure that the appliance can be

separated from the power supply by an isolator that dis-

connects all poles with at least 3 mm contact separation.

WARNING Electrocution

Ensure that the appliance is earthed.

!

Material damage

Observe the type plate. The specified voltage must match

the mains voltage.

f

f Pull off the temperature selector.

f

f Undo the screws at the bottom of the control panel cover and

remove the cover.

f

f Prepare the power cable and feed it through the cable grom-

met into the control panel. Select a cable with a cross-section

suited to the load of the appliance.

f

f Connect the required load in accordance with the connection

examples (see chapter "Specification / Wiring diagrams and

connections").

f

f Fit the control panel cover.

f

f Push on the temperature selector.

f

f Use a ballpoint pen to mark the selected connected load and

voltage on the type plate.

11. commissioning

11.1 commissioning

f

f Open a draw-off point until the appliance has filled up and

the pipework is free of air.

f

f Adjust the flow rate. For this, observe the maximum permis-

sible flow rate with a fully opened tap (see chapter "Specifi-

cation / Data table"). If necessary reduce the flow rate at the

butterfly valve of the safety assembly.

f

f Carry out a tightness check.

f

f Turn the temperature selector to maximum temperature.

f

f Switch the mains power ON.

f

f Check the function of the appliance.

f

f Check the function of the safety assembly.

11.1.1 appliance handover

f

f Explain the appliance function to users and familiarise them

with its operation.

f

f Make the user aware of potential dangers, especially the risk

of scalding.

f

f Hand over these instructions.

11.2 recommissioning

See chapter "Commissioning".

12. settings

12.2.1 limiting the temperature selection
You can adjust the temperature selection limitation beneath the

temperature selector.
Factory setting: Limited to 60 °C

f

f Set the temperature selector to "cold" and isolate the appli-

ance from the power supply.

f

f Remove the temperature selector and the control panel

cover.

1

2

26

�0

2�

79

�0

07

0

1 Limiter disc

2 Without limiter disc, maximum 82 °C

f

f You can set the limit to 45 °C / 60 °C by rotating the limiter

disc. After removing the limiter disc, the maximum tempera-

ture can be set.

f

f Replace the control panel cover and temperature selector.

13. shutting down

f

f Disconnect the appliance from the mains at the MCB/fuse in

the fuse box.

f

f Drain the appliance. See chapter "Maintenance / Draining the

appliance".

Advertising