the calorific capacity and pressure of the gas vary according to the type of gas.
When changing the gas, the technician should successively : change the jets, make the gas connection to the installation and set the
minimum flow of all the gas burner tap.

CHANGING THE GAS TYPE :

3 GB

INSTALLATION

• Factory setting :

Natural gas = G20-20 mbar/G25-25 mbar

Gas setting possible according to installation
Butane gas G30-29 mbar or Propane gas
G 31-37 mbar

• CHANGING THE GAS TYPE

Hob burner jets
To gain access to the jets :
- lift the hob lid,
- remove the top, grills, caps and

heads of all burners,

- use a tube spanner (7) inside the

burner,

- according to the information given

in the table, install jets suitable for
the burner type and gas type
supplied.

For reinstallation, fit the heads, burner
and top grills.

JET

Each jet is identified with a mark.

AUXILIARY

G20 20 mbar

G20 25 mbar

G25 25 mbar

G30 29 mbar

G31 30 mbar

Jet

kW

Jet

kW

Jet

kW

Jet

kW

1,00

1,20

0,90

76

G31 37 mbar

Front right

Rear left

Front left

Resr right

SEMI-RAPID

RAPID

ULTRA-RAPID

50

0,90

1,00

1,00

101

66

1,75

2,00

1,60

1,60

1,75

1,75

118

80

2,50

2,80

2,30

2,25

2,50

2,50

144

94

3,50

4,00

3,20

3,20

3,50

3,50

BURNER

• CHANGING THE JETS OF THE GAS BURNERS

By-pass screw

Warning :

Never loosen

the others

screws !

• SETTING THE IDLE FLAME

If the gas type has been altered, the stability of the flame in the minimum flow
must be checked and set by adjusting the by-pass screw.

To access the top burner by-pass screw, remove the control panel knobs.

a) Butane- propane gas :
the setting is done by screwing right in (without forcing) the by-pass screw
whose calibrated hole provides the minimum flow.
b) Natural gas :
- unscrew the by-pass screw one turn,
- replace the knob, light the burner and set to low flame,
- remove the knob again, screw the by-pass screw until a

reduced flame is obtained, staying stable when going from high to low position.

- replace the knob.

CAT.

G20/20 G20/25 G25/25 G30/29 G30/36 G31/30 G31/37

II 2E+3+

BE-FR

II 2H3+

CH-ES-GB

IT-PT

II 2H3B/P CZ-DK-FI

NO-SE

II 2H3B/P HU

I 2E

DE

II 2L3B/P

NL

GAS/GAZ/Pression (mbar)

II 2ELs3B/P PL

G350/13

Advertising