Clustered mpio host computers, Advanced functions, Figure 5-2 clustered server environment – Accusys ExaRAID GUI User Manual

Page 178

Advertising
background image

Advanced Functions

5-5

Clustered MPIO Host Computers

For clustered host computers sharing single RAID system, the storage is to
be accessed simultaneously by all host computers. In such case, one host
group should be created for all host computers, and a host group should
include all HBA ports on all clustered host computers. So, all host
computers can have the same LUN mappings from all paths.

Figure 5-27 illustrates two clustered servers sharing single RAID system with
multi-path I/O. Both servers see the same two LUNs (DG0LD0 and
DG0LD1), each of which has two paths.

Add WWPN of HBAs to hosts

HBA0 WWPN -> Host 0

HBA1 WWPN -> Host 1

HBA2 WWPN -> Host 2

HBA3 WWPN -> Host 3

Add hosts to each host group

Host 0 and Host 1 -> Host Group 0

Host 2 and Host 3 -> Host Group 1

Map LUNs to host groups

DG0LD0 and DG0LD1 -> Host Group 0

DG1LD0 and DG1LD1 -> Host Group 1

1

2

3

4

5

6

1

2

3

4

5

6

7

8

9

10

11

12

7

8

9

10

11

12

Server1

(with Pathguard installed)

FCP1

FCP2

FCP2

FCP1

Server2

(with Pathguard installed)

WWPN

WWPN

WWPN

WWPN

Storage Group

(for Host Group 0)

LAN

LUN0

(DG0LD0)

LUN1

(DG0LD1)

LUN2

(DG1LD0)

LUN3

(DG1LD1)

HBA1

HBA0

HBA3

HBA2

Host Group 0

Fibre Switch

(SAN)

Figure 5-2 Clustered server environment