Section 5 - troubleshooting, Error messages, Tool does not power up – Actron CP9175 OBD II AutoScanner User Manual

Page 47: Troubleshooting 5, Error messages -1 tool does not power up -1

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 5 – 1

Troubleshooting

5-1

Section 5 – Troubleshooting

Error Messages

Check the following if an error message displays:

❒

Make sure vehicle is OBD II compliant.

❒

Verify ignition key is ON and not in the ACCESSORIES
position.

❒

Make sure cable connects to vehicle’s Data Link
Connector.

❒

Look at Data Link Connector and check for cracked or
recessed pins, or for any substance that could prevent a
good electrical connection.

❒

Check for bent or broken pins.

❒

Check for blown fuses.

❒

Make sure the vehicles control module has a good
ground.

❒

Verify battery voltage is at least 8.0V.

❒

Verify the control module is not defective. Refer to the
vehicle service manual to diagnose the control module.

Tool Does Not Power Up

✓

Review “

Safety Precautions

” before troubleshooting.

Do the following if the tool will not power up, communicate with
vehicle’s Control Module, pass Tool Self-Tests, or functions
incorrectly in any other way:

❒

Check Data Link Connector pins.

❒

Reconnect Data Link Connector.

❒

Check vehicle battery to make sure at least 8.0 volts is

present.

❒

Contact Technical Support.