Dell DX6004S User Manual

Page 11

Advertising
background image

Getting Started With Your System

9

Heat dissipation

1571 BTU/hr maximum (non-redundant
power supply)

1666 BTU/hr maximum (redundant
power supply)

Maximum inrush current

Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 25 A per power supply for
10 ms or less

Batteries

System battery

CR 2032 3.0-V lithium coin cell

Physical

Height

4.29 cm (1.69 in)

Width

43.4 cm (17.09 in)

Depth

61.26 cm (24.12 in)

Weight (maximum configuration) 15 kg (33.02 lbs)

Weight (empty configuration)

5.96 kg (13.12 lbs)

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour

Relative humidity

Operating

8% to 85% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing)

Power (continued)