INSTALLATION INSTRUCTIONS

M S D

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

ALTERNATE TIMING CURVE

AltCurve – (Default - See Graph)

The Midget Ignition allows you to

program a timing curve that is only

active when the Alt Wire is switched to

+12V. When this curve is active the word

active appears on the bottom of this

graph. This curve is programmable by

the graphical map. The easiest way to

achieve this is to maximize the box that

contains the Alt Curve. In order to move

the curve you will need to place your

mouse over the portion of the graph that

you would like to move. Right click your

mouse and select “Add Dot”. This will

give you a red dot that you will be able

to position anywhere along the curve.

Continue to do this until your curve is

completely mapped out. After this curve

has been edited, save it in the Midget

Ignition with a transfer - Plot to MSD or

File-Save As to save it in a file on the PC.

RUN TIMING CURVE

RunCurve – (Default - See Graph)

The Run Curve is active when the

Alt Wire is not switched to +12V. The

Midget Ignition gives you the ability to

map out a complete timing curve from

800 rpm all the way to 15,000 rpm. This

timing curve can increase or decrease at

any point along the graph. The easiest

way to achieve this is to maximize the

box that contains the Run Timing Curve.

In order to move the curve you will need

to place your mouse over the portion of

the graph that you would like to move.

Right click your mouse and select “Add

Dot”. This will give you a red dot that you

will be able to position anywhere along

the curve. Continue to do this until your

curve is completely mapped out. After

this curve has been edited, save it in the

Midget Ignition with a transfer - Plot to

MSD or File-Save As to save it in a file

on the PC.

Note: Any graph can be printed by se-

lecting Transfer-Print. Also all other

parameters can be printed from the Data Editor-Select-Print.

^Rpm 800 Alt