MONITOR

The rpm meter is a graphical interface that

allows you to monitor the rpm and retard func-

tions of the Midget Ignition while the engine is

running. The dial on the left side will indicate

the rpm in real time. The dial on the right side

will show the total degrees retard.

DEFAULT SETTINGS

The default settings are for a four cylinder engine with a Waste Spark (two spark plugs fire

at the same time). This ignition should only be used on 4-cylinder engine with two mag pickup

inputs, with two coils.

The following list shows all of the default values and adjustable increment of the Midget Ignition.

REV LIMITER OPTIONS

RevMax – (Default 9,500)

This is the Max Rev Limiter. The options are from 2,000 rpm to

15,000 rpm in 100 rpm increments.

START RETARD OPTION

Start retard is used to ease the load on the starter and to prevent

backfires. This option is in effect from 0 to 800 rpm on start up. If

the engine drops below 500 rpm, it will activate again. It is adjust-

able in 1° increments from 0° - 25°. The default is 15°.

Display

Default

Data Low-High (step by)

RevMax ###00 Rpm

9,500

2,000-15,000 (100)

StartRetard ## Deg

15

0-25 (1)

BattType $$$$$

Lead

Lead, NiCad, NiMH

BattCells ##

6

6-12 (1)

RunMap Rpm ###00

800

800-15,000 (100)

RunMap Deg ##.#

0

0-25.0 (0.1)

AltMap RPM ###00

800

800-15,000 (100)

AltMap Deg ##.#

0

0-25.0 (0.1)

AlertsPerScan #

0

0-1 (1)

RevLim
RevMax

Retards
Starts
StartRetard
*Deg 10

Figure 6 RPM and Retard Monitor.