Idle RPM Target: Select the rpm that the engine should idle

at. The rpm range is adjustable in 25 rpm increments

(Figure 31).

Note: Running too high of an idle speed in an automatic

transmission equipped vehicle with a stock torque

converter can cause idle issues in gear.

Rev Limit: The rev limiter can be set as a fuel cut-off or ignition

cut-off limiter. The default setting is as a fuel cut-off

limiter set at 6500 RPM. The programming range for

both rev-limiters is 3000 RPM-10,000 RPM (Figure 31).

The ignition cut should only be used on race vehicles

with a very free flowing exhaust.

DO NOT use with

catalytic converters or severe damage may result!

Variable Cam Timing: The Atomic LS truck system supports

the factory Variable Cam Timing. The default setting

is set at Disable. Change the setting to Enable for use

with a factory VVT engine (Figure 31).

Once all of the settings in the Initial Setup menu are selected,

the Atomic has enough information to start and run the engine.

It is recommended to scroll through the advanced settings to

program selections that may be useful after the initial start up

(such as the cooling fan activation temperatures).

ADVANCED SETUP

The Advanced Setup features are optional as the Initial Setup

menu provides the Atomic EFI with the values needed to run

the engine. Features in the Advanced Menu are designed to

deliver additional features and advanced tuning functions to

further enhance the drivability and overall performance of the

engine.

Fans: This setting sets the temperatures to activate two electric

fans. Each circuit will be activated by supplying ground

through the Red (Pin A) and Orange (Pin H) wires of

the GT-Series 16 pin harness from the Power Module. A

relay is required for both circuits since those wires are a

low current ground. The fans will activate at the desired

temperature and will remain on until the temperature

falls below 10° of the setting. Settings are 100°-300°F

(Figure 31).