9

Step 3

Do a Reverberation Measurement

To proceed to a reverberation measurement, select an element to measure in the table of the main

panel and click the button

to open the measurement interface.

Once in the measurement panel, click on the

button to start the reverberation

measurement. The acquisition end by itself once the number of averages is reached.

Click on the

button to accept the measurement.

• An omnidirectional should be used

• A first source position should be in center of the receiving room.

• Several fixed microphone locations should be used.

• Keep the microphone at least 1 meter away from any major extended surface.

• Keep the microphone at least 1 meter away from the source.

• The more source positions and the more microphone position, the more the reverberation

time will be representative.

Start the

Measurement

Accept the

measurement