21

Once the measurement is acceptable, press the Accept button to return to

the main interface.

7.2.1

Reverberation: Time Decay

This display shows the response to a noise interruption. It also superimposes the curves used to

evaluate the reverberation time values and the averaged successive responses.

Figure 4: Time Decay tab of the reverberation

Time Decay Graph

This graph displays the time decay curves for the selected frequency band

or global.

These buttons are used to select the visible curves on the time decay

graph. T10, T20 and T30 are the straight lines used to determine the

reverberation times. All shows all the iterations in the averaging process.

These buttons are used to display the next or previous frequency band on

the time decay graph and in the results.

This button is used to switch between frequency bands and global.

This array displays the computed results for the selected frequency band or

global.